Description
DALY BMS 17S 60V 40A Lithium ion with Balance leads.
DALY 17S Li-ion 40A
Introduction about this BMS:
This is a 17S fixed configuration basically it cannot be used for any other battery pack configurations. Because it is only a Lithium ion battery management system only. As a result that they cannot be used for LiFePo4 and Li-Metal or LTO batteries.It is strictly for Li-Ion battery packs only.
Over charge and over discharge protection:
The Li-ion battery pack will stop charge after the cell voltage reaches 4.25V and stop discharge when its voltage reaches 3V.
Temperature Protection:
In high temperatures the bms ranges from 70℃ discharging battery protection.
Meanwhile in low temperatures the bms ranges up to -20℃ battery protection.
Short circuit protection:
When there is a defect or damage to the circuit at same time the bms will shut down the whole Battery.
Certifications Approved:
ISO/ FCC/ RoHS/ PSE and CE APPROVED
Applications:
Solar and RV, Electric bikes and Skateboard including camping boats and Power tools, Lawn moving and household energy storage systems etc.
What you will get:
- 17S Li-ion 40A rated voltage with 60V BMS
- Balanced wire sense cable (18 Wire sense cable with connector)
- Instruction Manual
Conclusion:
Most important that it is only a waterproof bms available in lithium industry.
This BMS is also for all kinds of lithium-ion cells including 18650 ,21700,36500 cylindrical cells and prismatic cells.
DESCRIPTION | SPECIFICATION |
---|---|
BATTERY TYPE | Li-ion |
Continue discharge current | 40A |
Peak current | 120A±20A |
main circuit inner resistance | ≤ 20mΩ |
Charge Voltage | S*4.25V |
Charge Current | 20A |
Over charge detect voltage | 4.25 ± 0.05V |
Over charge protection delay | 1 Sec |
over charge release voltage | 4.15 ± 0.05V |
Balance detect voltage | 4.18V |
Balance release voltage | 4.18V |
Balance current | 30± 5mA |
Over discharge detect voltage | 2.7 ± 0.1V |
Over discharge detect delay | 1 Sec |
Over discharge release voltage | 3.0 ± 1.0V |
Over current detect delay | 1 mS |
Over current detect voltage | OFF LOAD |
Short circuit protection condition | Short circuit external load |
Short circuit detect delay | 250µS |
Short circuit protection relay condition | Off load |
Temp protection | Charge <-5 ͦ C or >50 ͦ C
discharge < 70 ͦ C |
working current | 100µA |
Sleeping current (when in discharge) | 20µA |
Working temp range | -20 ̴ 70 ͦc |
Sleeping temp range | -40 ̴ 80 ͦc |
Weight | 8 ounces |
Size | 2.6*3.1*0.6inches |
Wiring Diagram | Daly wiring diagram |
Example for Daly BMS Wiring Diagram:
https://dalybms.com/16s-bms-wiring-tutorial/